PCSF Master and PCSF Plugin

You are here:
< Back

 A PCSF Master device (POCType=71,73) controls several slave wells (POCType=72,74). You will need to scan the Master to get the firmware version. It will likely error out, but if you refresh the status screen, it should show the version number. After you have the FW Version add a new well. It is easiest to clone the master, then uncheck the clone button and change it from a master to a well. When creating the slave devices go to Asset>Configuration>Muti-well Setting and then choose the well number 1-8.

The master device and well 1 will have the same node address. Wells 2-8 will have an incremented offset starting at well 2 = 2048, well 3 = 4096, etc… This offset will display in tblNodeMaster. tblWellDetails will also show the WellNumber for each device

You will have to scan the well a couple of times, and may need to scan the master in between to get everything communicating. If you get comm errors, just scan them both back and forth a few times.

You must create a master for the PCS Plugin to work in the XSPOC desktop client.