Fisher ROC Communication Initial Setup

You are here:
< Back

POCTypes:

  • 45 Fisher ROC Single Meter
    • Supports ROCLink protocol
    • tblParameter entries exist for a single gas flow meter
    • used for FloBoss 107 Single gas flow meter installations
  • 46 Fisher ROC800 Master Controller
    • Supports ROCLink Plus protocol
    • tblParameter entries exist to determine number of slave devices
    • Scan creates required slave devices based on registers read
  • 108 Facility Fisher ROC800
    • Supports ROCLink Plus protocol
    • no pre-existing tblParameter entries
    • Scan does not automatically create slave devices
    • Expectation is that Facility tags will be used for data
  • 110 Facility Fisher ROCLink
    • Supports ROCLink protocol
    • no pre-existing tblParameter entries
    • Expectation is that Facility Tags will be use for data
    • For FloBoss 107 devices other than single gas flow meter installations.
  • 281 EFM Fisher ROC Gas Orifice
    • Supports ROCLink Plus protocol
    • tblParameter entries exist for a Gas Orifice flow meter
    • used for one of multiple Gas Orifice devices implemented on a ROC800 Master controller
    • Usually automatically created when the ROC 800 master is scanned
    • Cannot be used for FlowBoss 107 Gas Orifice because the registers don’t match.
  • 282 EFM Fisher ROC Gas Turbine
    • Supports ROCLink Plus protocol
    • tblParameter entries exist for a Gas Turbine flow meter
    • used for one of multiple Gas Turbine devices implemented on a ROC800 Master controller
    • Usually automatically created when the ROC 800 master is scanned
  • 283 EFM Fisher ROC Liquid Turbine
    • Supports ROCLink Plus protocol
    • tblParameter entries exist for a Liquid Turbine flow meter
    • used for one of multiple Liquid Turbine devices implemented on a ROC800 Master controller
    • Usually automatically created when the ROC 800 master is scanned
  • 284 EFM Fisher ROC 107 Gas Orifice
    • Used for a multiple Flow Meter FloBoss 107, Create 1 for each orifice.
    • Node Address “offset” is 1 for Orifice 1, 2 for Orifice 2, etc.
    • tblParameter entries exist for Gas Flow Orifice Meter
    • Not automatically created and no “Master” exists.
    • Supports ROCLink protocol
    • Cannot be used for ROC800 Gas Orifice because the registers don’t match.

Host Address

  1. The Fisher ROC protocol requires a SystemParameter “EFMFisherROCHostAddress”
  2. This needs to be a string of the form “000001” where the first three characters “000” is the “Host Address Group”
  3. And the second three characters “001” are the “Host Address Unit”.
  4. If this is not setup, XSPOC will use the default of 0 and 1 as shown above.

Device Address

The Fisher ROC “Meter Address” should be also in the form “001003”.

  1. The first three characters are the “Group” (1 in this example) and the second three are the “Unit” (3 in this example).
  2. This goes in the “Address” field in the WellConfig screen. This field is also called “Node” in the tblWellMaster.
  3. For example”i10.10.10.10|111|001003″ would be the example above of group 1 and Unit 3 for a device on
  4. TCPIP address 10.10.10.10 and TCPIP Port 111.