How Can We Help?
Search for answers or browse our knowledge base.
-
Ally
-
- Articles coming soon
-
- Articles coming soon
-
- Articles coming soon
-
- Articles coming soon
- Articles coming soon
-
-
Internal Only
-
- Articles coming soon
-
- Manually remove from uninstall list
- Find orphaned history via sql
- PCSF Wellvision
- Change from Windows Auth to XSPOC Auth
- Speed up a Slow Database sp_updatestats
- Export import single well
- XSPOC module licenses
- Import Export Single Wells - Employees Only
- Copy group to new parent
- Motor Load
- Clone Parent Group with a new name
- Load Wells Worksheets
- Compare Database Script
- XSPOC Database Columns
- Theta VPN DNS Settings
- Facility Tags
- Show all articles ( 1 ) Collapse Articles
-
-
Standalone Products
-
XSPOC Software
-
- Automatic Chemical Control
- CollectCards Event Explained
- Lufkin SAM SPM Calculation
- Offset and Scale Factor
- ESP Valiant Motor Current is Calculated
- ESP Documentation
- Purdue Diagram - XSPOC
- System Parameter Info - XSPOC
- Connection Strings
- DataTypes UnitTypes
- XSPOC Gas Lift Analysis Input Guide
- XSPOC ESP Analysis Input Guide
- Alarm Actions
- Smarten Live Default Login
- Max # of lines in deviation profile
- Param Standard Types in Facility Tags
- Setpoint Optimization Info
- Group Status Calculated Column
- XSPOC Database Tables Related to Totalflow Communication
- New ParamStandard Type PST
- ESP Analysis Requirements
- Uplift Opportunities Required Data
- Group status conditional format
- Manually Collect and Process DYNO Cards
- Lufkin SAM Run Statuses
- Log Comm Messages
- Precedence Logic for ESP - how data is stored
- XSPOC Table Info
- POC Types In XSPOC
- Terminal Servers (Digi One-Black box)
- SQL Security Requirements for SpocWrite account
- SPC - Statistical Process Control
- Software Introduction
- System Requirements - XSPOC
- How Does XDIAG determine Out of Balance
- Group Status - Percentage RTY Yesterday's Run Time definition
- Well Status Screen
- XSPOC Lookup Tables
- Communicating with EFM Fisher ROCs
- FAQ How Do We Account For Wells In Different Time Zones
- Table IDs
- Importing .dyn files to Theta Software
- Components of XSPOC
- ABB TotalFlow Device Support in XSPOC 2
- ABB TotalFlow Device Support in XSPOC
- POCTypes
- Host Alarms
- Applications
- XSPOC Database Tables Related to Fisher ROC Communication
- Fisher Roc Register Addressing
- Fisher ROC Communication Initial Setup
- Show all articles ( 36 ) Collapse Articles
-
- Recover A Deleted Well
- XBAL Template Missing
- Using Register Block Limits
- Increase Scheduled Events Intervals
- Window Screen
- Tiny Gateway Setup Communications
- Parameter Trending
- Lufkin 2.0 - Cyclic Steam Injection Pressure Monitoring
- Add Parameter Trending By POCType
- Offset and Scale Factor
- Shutdown Group from Facility Tag
- Data Views
- Well Type (Expected Operation) VFD Variable Speed
- XSPOC Hosting New User Setup
- Adding Chemical Pump Control in XSPOC
- Well Group to Show Wells That Haven't Had a Card Pulled in 24 Hours
- SQL Profiler for troubleshooting
- Add new date formats in group status
- Well Addresses and communication options
- DoFastScan in tblSchedule
- Allen Bradley Device Communication
- Configuring High Resolution Historical Data Storage
- Calculated Tags
- PCSF Device Communication
- PCSF Master and PCSF Plugin
- Measurements in Data History
- Using TLS 1.2 with XSPOC
- Well Test Email Importer Setup
- Connection Strings
- XSPOC Gas Lift Analysis Input Guide
- XSPOC ESP Analysis Input Guide
- OpenWells Integration
- Disable Codes
- Generate an XSPOC License Certificate File
- Default windows views
- Disable ELAM for individual wells
- Reset / update database stats
- External Data Query Default
- Powershell script to count processes
- Encrypted Password
- Loopback Echo test at the well
- Add a Custom Controller POCType
- Adding a Custom Pumping Unit to XSPOC
- Moving a Data Base from One Drive to Another Drive
- Morning Reports
- Main Client Window
- Logging Comm Traffic for a Port or Node
- Limit User Navigation to a Group
- License Manager
- HOW TO Configure Generic Well Test Import
- HOW TO Configure WellView Import
- How to delete change trend data points from History Graph
- How to Generate XSPOC License File
- How to setup Admin message to all users
- PMC Salt Register explanation
- POC Modes
- POC Trends Window
- Positioning the Pump-Off Setpoint
- Run XBAL from XSPOC
- Recreate Data History Indexes
- Register Panel Window
- Report WIndow
- Restoring an XSPOC system
- Run RODSTAR-V or RODSTAR-D from XSPOC
- Remote Shutdown of Lufkin VFD
- Installing XSPOC Mobile
- Set up Hi Lo Alarm Callout
- Setting up Register Logging for a Lufkin SAM in XSPOC
- Send Write Sequences to Wells
- Split Installation
- SQL View for XDiag required data
- System Parameter DisableCustDBUpdate
- Set up a Discrete Alarm Callout
- Setpoints Window
- Setting the Number of Weeks to Store Dynamometer Cards
- Standalone Product Installation Guide
- Shutdown Start Clear Well With tblCommandActions
- Starting Rodstar
- Modbus comm setup
- tblPortMaster Settings
- To Add an Automatic Scheduled Call-Out (verify system is working)
- Using Read-Only Fields in Well Config
- User Permissions Security Settings
- Updating the license on the Sentinel
- Upgrade SQL Express to Standard or Enterprise
- User Security - Active Directory Group Security Configuration
- Invalid Connection String Attribute
- How to update the HASP config file
- ABB TotalFlow Device Support
- Moving an XSPOC system
- HOW TO Install the Data Integration Module
- Scheduled Events and Descriptions
- Other Well Measurements Window
- Network Seamless Installation for xsClient
- Comm Status Alarming by Comm Channel
- HOW TO Configure Generic Data Export
- HOW TO Configure Data Integration (Start Here)
- How To Change SpocWrite Password
- How to Adjust XSPOC Field Labels
- How to Add OPC Servers to XSPOC
- How to activate your Theta software
- HOW TO Use the OLE DB Client application
- HOW TO Create a Branch
- Obtaining Run Status for Baker Weatherford or WellPilot
- Host Alarms
- History Graph Window
- Group Alarm History
- Group Well Test History
- Group Status Window
- Group Status Views Setup
- Group Status Columns - Merge Similar Columns
- Group Parameter Trending
- Group Builder
- Graph Settings Window
- Using a Digi Terminal Server
- Well Notes Window
- View Multiple Cards
- XSPOC Database Window
- Add a Parameter to Group Status View
- Add an Analog Input
- Application and Database Server Install of XSPOC
- Card Viewer
- Configure Standalone Product Launch from XSPOC
- FAQ How Do We Account For Wells In Different Time Zones
- FAQ Share a comm channel
- FAQ Monitoring Power
- FAQ Why don’t I see my xsScannerL and xsCommServer icons in the task manager
- Field Maps
- Granting Higher Level Access for Users
- HOW TO Configure Generic Data Import
- Facility Status Window
- Facility Reports
- External Data Query Setup
- External Data Query
- Export Data History Window
- Energy Mode
- Email to Text
- Email Notification Setup
- Email Configuration in XSPOC
- XSPOC Database Merge (Well Sale Only)
- Cumulative Production Limits
- Control of XSPOC Wells from Another Program
- Configuring Facility Tags
- Configuring Exception Groups
- Configuring Analog and Digital Input Registers
- Comm Status Alarming by Comm Channel
- Collection Modes
- Changing Phrases in the Client
- Card Viewer
- XSpoc Backups
- Back up Database Using Scheduler
- Associate User Views
- Assigning Custom Icons to Custom POCs
- Archive Options in XSPOC (ArchiveDataHistory SP)
- Adding an All Call to the system
- Alarms
- Adding Custom Event Groups for Well Notes
- Adding A New Well
- Add Parameters - Setpoints Control Panel
- Add New Well
- Add an Analog Input
- Add a Port into Configuration Table
- XSPOC Database Merge (Well Sale Only)
- Show all articles ( 148 ) Collapse Articles
-
- Articles coming soon
-
- Sierra Wireless config
- XSPOC General Troubleshooting Tips
- Large Database Transaction Logs
- Error deleting group <missing>
- Unable to convert raw value error
- User already exists in the current Database
- Member HostName of connection is invalid
- Unlocking a Deadlocked SQL Database
- Rodstar file cannot be located for this well.
- History Graph missing data
- Missing Data points on Mobile History Graph
- Missing Font causing Group Status error crash
- PumpingUnitID CAB## problem
- RODSTAR XROD XR NullReferenceException Object Instance Error Entity Framework
- Troubleshooting Card Viewer Problems
- Troubleshooting License Issues
- Troubleshooting Tubing Movement
- HASP driver install fails
- Well Test Date Range Error
- Well Pilot Draw Cards in Run Constant Mode
- Wells not scanning - Troubleshooting
- XDIAG doesn't start, timeout
- XSManager crashes upon launch
- Cannot Add Additional Comm Ports And The Correct Number Of XSCommServer.exe Processes Will Not Launch
- Can't Get Analysis
- Locked columns in the Database
- FAQ Are there XSPOC client errors log
- FAQ Connection to the server could not be established
- FAQ Downhole card missing on Card Viewer
- Missing Manufacturer on the pumping unit list
- Function Validate Registration fails
- tmpout.dat error saving a key in License Key Manager
- Err# -2147217900
- DBMods error Quoted Identifier is set to OFF
- Show all articles ( 19 ) Collapse Articles
- Articles coming soon
-
New ParamStandard Type PST
Created On
byAndrew Binning
You are here:
< Back
1. Find the applicationID for the controller you want in tblApplications (Rod lift=3, ESP=4, Gas Lift=7, Tank=12, Facility=18)
2. Add a new PST for that application in tblApplicationParamStandardTypes using the ID from #1. the PST should be above 10,000
3. In tblParameters find the register you want to add the PST to and enter in the PST number you created.
4. In tblParamStandardTypes Create a new PST using the same number used in tblApplicationParamStandardTypes. UnitTypeID=0, PhraseID=0
5. Restart Services
