by Theta Team | Feb 25, 2021
XSPOC System Requirements These are some general guidelines for hardware and software needed to install and run XSPOC. Although these suggestions may vary from one company to another, these requirements can be used as a general guide for initial setup and...
by Theta Team | Jan 29, 2020 | Public News, Software Release Notes
Application Enhancements: ESP Data Analytics – New product that utilizes data analytics and historical ESP data to identify operating conditions like gas interference, a plugged stage, or a broken shaft. Rod Pump Setpoint Optimization – New capability that analyzes...
by Theta Team | Dec 20, 2022
What’s New! The XSPOC 3.2 release expands on the artificial intelligence (AI)-driven autonomous control capabilities that were introduced in the 3.1 version, while also adding new features around uplift and economic opportunities for both rod- and gas-lifted...
by Jeremy Hasley | Jan 6, 2022
Question concerning Setpoint groups and their association with the POC type. I see the setpoint group number in the Setpointgroups table. I also see the setpoint group number in the Parameters table associated with each individual parameter. Is this the only place the...
by Theta Team | Mar 9, 2021 | Public News, Software Release Notes
XSPOC 3.1 Release notes 3/9/2021
One of the most advanced and exciting algorithms in 3.1.0 is the autonomous idle time setpoint optimization.
by Theta Team | Dec 13, 2022 | Public News
Notice: XSPOC email notifications may stop sending emails due to deprecated security implementation within Microsoft O365 and Exchange Online. If you are using Microsoft Office 365 and or Exchange Online to relay SMTP (mail) messages and reports from XSPOC to internal...
by Theta Team | Feb 5, 2020 | Software How To
WELL COUNT: To accurately produce your quote, an INFO.EC file will be needed. Email the file to Jody.Banducci@apergy.com. Below are the instructions needed to complete this process. Instructions For XSPOC Versions 2.5.0 through 3.0.0: Please provide the EC file from...
by Andrew Binning | May 14, 2020 | Public News, Release Notes
RODSTAR 2020 Rel 1: New and updated pumping units New and updated rod grades Improvements made to minimum and maximum axial loads calculations to help some problem deviated cases Improvements made to automatic-batch option with better logging to help with running more...
by Adam Pecharich | Mar 7, 2022
Can system parameter TCPAutoDisconnect be configured in 3.0? Terry has been working with Weatherford (Prabhu) and discussing if that is an issue for us.